CONDOR DC POWER SUPPLIES INC.
2311 STATHAM PKWY
OXNARD, CA 93033 + 805-486-4565
RATINGS:
Input: 100-240 V ac, 2.5 A, 50/60 Hz
Outputs:
2XWSXW 2XWSXW 2XWSXW 2XWSXW
02'(/
1RWH 1RWH
1RWH 1RWH
1RWH 1RWH
1RWH 1RWH
*3)0$ 9 $ $ 9 $ $ 9 $ $ 9 $ $
*3)0% 9 $ $ 9 $ $ 9 $ $ 9 $ $
*3)0& 9 $ $ 9 $ $ 9 $ $ 9 $ $
*3)0' 9 $ $ 9 $ $ 9 $ $ 9 $ $
*3)0( 9 $ $ 9 $ $ 9 $ $ 9 $ $
*3)0) 9 $ $ 9 $ $ 9 $ $ 9 $ $
*3)0* 9 $ $ 9 $ $ 9 $ $ 9 $ $
*3)0+ 9 $ $ 9 $ $ 9 $ $ 9 $ $
50 W max. total power, convection cooling.
80 W max. total power, convection cooling, unit mounted to min. 12 x 12 x 0.125 in. thick aluminum plate.
125 W max. total power with min. 200 LFM airflow over unit.
125 W max. total power with min. 250 LFM airflow over unit, with optional cover (-C suffix).
Notes: 1. Maximum ratings with convection cooling.
2. Maximum ratings with forced air cooling.
3. Maximum ambient temperature for rated output power is 50°C.
4. Maximum Operating Relative Humidity 96%, no condensation.
5. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions
before application of power.
CERTIFICATION: All models are Certified to be in compliance with the applicable requirements of UL 2601-
1, CSA 22.2 No. 601.1-M90, EN 60601-1: A2 (1995).
CLASSIFICATION:
(5.1) Protection against electric shock = Class I
(In accordance with sub-
clause 5 of IEC 601-1)
(5.2) Degree of protection against electric shock = Not acceptable for applied part without
additional isolation (contact factory for details)
(5.3) Protection against harmful ingress of water = Ordinary (no protection)
(5.5) Have not been evaluated for use in the presence of a flammable anaesthetic mixture with
air, oxygen, or nitrous oxide. This evaluation is to be made on the end equipment by the OEM.
(5.6) Mode of operation = Continuous
SAFETY DECLARATION: Condor DC Power Supplies, Inc. declares
under our sole responsibility that all models listed above are in conformity with the
applicable requirements of EN60950 following the provisions of the Low Voltage
Directive 73/23/EEC.
GROUNDING: The Functional Earth (Ground) terminal J1-5 and/or chassis must be bonded to Protective Earth
in the end application. Using J1-5 for the end product protective earthing terminal is not recommended. A
separate dedicated protective earthing point should be used.
OUTPUTS: Output common or return should be connected to Protective Earth in the end application. The
outputs are intended for Protectively Earthed Signal Output and Intermediate Circuits only. The outputs are not
acceptable for patient connection without additional isolation. The DC outputs are SELV under normal and
single fault conditions.
41-34961-0001 Rev. C 02/07/01
Page 1 of 2
INSTALLATION INSTRUCTIONS
GPFM125 SERIES
Vue de la page 0
1 2

Résumé du contenu

Page 1 - GPFM125 SERIES

CONDOR DC POWER SUPPLIES INC. 2311 STATHAM PKWY OXNARD, CA 93033 + 805-486-4565 RATINGS: Input: 100-240 V ac, 2.5 A, 50/60 Hz Outputs:  2XWSXW

Page 2 - C O N N E C T I O N S

INSTALLATION INSTRUCTIONS GPFM125 SERIES OVERVOLTAGE PROTECTION: Output #1 on all models, and #2 (GPFM125G & GPFM125H only) are monitor

Commentaires sur ces manuels

Pas de commentaire